Rate & Roof

Von Ormy, TXLocal --:--Sun now --Daylight today --

Sun on a roof in Von Ormy.

The PVWatts model puts a generic roof array in Von Ormy at 1,520 kWh a year for each kW of panels, using typical-year weather from a station 1.1 km away. A modeled estimate for a standard setup, not a measurement of any roof.

A year on one roof.

Scroll from January to December: the noon sun over Von Ormy climbs and falls, and the modeled output follows it.

Sun elevation through the day over Von Ormy The sun's path at latitude 29.28, computed from solar geometry. The upper dotted arc is the June solstice and the lower one the December solstice; the solid arc is the month being shown.
MonthAll 12 monthsNoon sun-Daylight-Modeled output per kW1,520 kWh

kWh per kW DC, modeled by PVWatts. Best month 153, weakest 95: a ratio of 1.61.

How Von Ormy comparesderived from the figures above

Where Von Ormy sits.

Von Ormy ranks 557th of 1220 Texas places modeled here, at the 54th percentile. Its 1,520 kWh per kW is above the Texas median of 1,515. The strongest months are August, July, June and the weakest are February, January, December; output peaks in August and bottoms out in February. In all, 29.5% of the year arrives in June, July and August, more than the 29.3% of the median place.

Closest modeled neighbors

  • Somerset, 6 km south: 1,504 kWh per kW, 16 less than Von Ormy.
  • Lytle, 14 km southwest: 1,510 kWh per kW, 10 less than Von Ormy.
  • LaCoste, 15 km west: 1,527 kWh per kW, 7 more than Von Ormy.
  • Castroville, 20 km northwest: 1,513 kWh per kW, 7 less than Von Ormy.
  • Natalia, 21 km southwest: 1,508 kWh per kW, 12 less than Von Ormy.
  • San Antonio, 24 km northeast: 1,505 kWh per kW, 15 less than Von Ormy.
  • Leon Valley, 25 km north: 1,497 kWh per kW, 23 less than Von Ormy.
  • Balcones Heights, 26 km northeast: 1,499 kWh per kW, 21 less than Von Ormy.
  • Sandy Oaks, 27 km southeast: 1,493 kWh per kW, 27 less than Von Ormy.

Against San Antonio

The nearest of the six largest modeled places is San Antonio, 24 km to the northeast, at 1,505 kWh per kW. Von Ormy models 15 kWh per kW (1.0%) above it. At 0.18 degrees of latitude apart, the two sit at almost the same sun angle, so geometry explains little. The weather station for Von Ormy is 1.1 km from the modeled point, against 2.2 km for San Antonio, so part of the gap can come from which station's typical year was used.

The second-nearest large place is Austin, 143 km northeast, where the same model gives 1,483 kWh per kW, so Von Ormy runs 37 above that figure. Against the Texas median place month by month, Von Ormy runs at least 2% higher in January, August, October, November, December. It runs at least 2% lower in February, April, May.

Electricity in Bexar CountyEIA-861

Electricity prices nearby

Providers listed in the county

They are the largest bundled providers whose EIA service territory lists the county. A county can list several, and which one serves a street depends on the address, so check your bill. Priced at the first provider's average, the modeled 1,520 kWh would come to $188 per kW a year, plain multiplication and not a savings estimate.

Modeled estimateruns in your browser

Size the array, see the kWh.

Scale the Von Ormy model to another array size, take off extra losses for shade or dirt, and price the energy at any rate. It is arithmetic on the PVWatts output above, nothing more: not a quote, not a savings estimate and not advice.

Starting rate: the Texas residential average of 15.4¢ per kWh. At that rate the modeled output is worth $234 per kW a year as plain multiplication.

Modeled estimate

Modeled output, kWh a year

9,120 kWh/yr

About - kWh in an average month. Priced at the chosen rate that energy comes to - a year, by multiplication only.

Assumes the same tilt, direction and equipment as the model below. Real output depends on the roof, shade, equipment and weather.

PVWatts v8station 652826

Month by month, per kW.

Modeled AC output in Von Ormy, Texas, kWh per kW DC, typical weather year
MonthkWh per kW
January104.4
February95.1
March124.7
April128.2
May137.1
June145.3
July149.9
August152.9
September132.9
October130.9
November110.3
December108.6
Year1,520

Model assumptions

System size
1 kWDC, results scale per kW
Mount
fixed roof mount
Tilt
20°
Azimuth
180°due south
Modules
standard
System losses
14%

Location 29.28, -98.66 (Von Ormy, population 1,215). Weather: typical-year data from station 652826, 1.1 km from that point.

Getting a measured number

A model cannot see your roof. Installers measure pitch, shade and the electrical panel on site. Quote marketplaces such as EnergySage, SolarReviews and WattBuy collect bids from local installers. Rate & Roof does not rank installers.

Texas electricity prices and providers

Next step

Payback, buyback.

The sliders above price the energy at one rate. The payback calculator adds the system cost and your buyback plan type, and shows every assumption. It is an estimate, not advice.

Email updatesdouble opt-in

Rates change. Get told.

One list, for Texas solar buyback plans. We write when a tracked rate changes and when new city data is published. Nothing else, and nothing until you confirm.

Read this first

  • A model estimate for a generic system at this point, not a measurement and not a promise of output.
  • Shading, roof pitch, equipment and local rates will differ.
  • All prices on this site are in cents per kWh unless marked otherwise. Bills are US dollars per month.

Credits and notices

The credits and notices that each data source requires are printed word for word with that source in the Sources list below.